+[* black] This step is the actual repair procedure.
+[* black] The error is caused by weakened shutter return spring, it doesn't have the power to close the shutter.
+[* black] Normally the motor opens the shutter curtain and engages the mechanism with a small neodymium magnet.
+[* black] When the electromagnet is activated, the neodymium magnet is disabled and the shutter curtain has to travel towards closing direction with the help of return spring.
+[* black] However, when the return spring is not strong anymore, so it cannot move the curtain.
+[* black] For repair, using a pair of tweezers, turn the spring adjustment wheel (the black round wheel with teeth) for 2-3 clicks towards the direction of green arrow.
+[* black] This should do it.