[title] Determine voltage absence
-[* black] After you wear insulated gloves, gently pull out the switch and use a Duspol or any other Voltmeter to test if there is voltage at the contacts.
+[* black] While wearing insulated gloves, gently pull out the switch and use a Duspol or any other Voltmeter to test if there is voltage at the contacts.
[* icon_note] You can also use a single pole phase tester, but that's not the proper way to do it.
[* icon_caution] Do not work on live circuits if you are not an experienced professional.