+[* icon_reminder] ***Re-assembly tip***—when you re-wire the replacement pump, attach the included fusible link to the longer, thicker black wire.
+ [* icon_caution] Do not use the previous pump's in-line diode.
+ [* black] Re-connect the pump's wires to the Rug Doctor's black and white wires.
+ [* icon_note] The fusible link should connect to the Rug Doctor's black wire.