crwdns2933423:0crwdne2933423:0

crwdns2933803:010crwdne2933803:0

crwdns2933797:0Alden Chucrwdnd2933797:0crwdne2933797:0

crwdns2936043:0crwdne2936043:0 crwdns2933505:0crwdne2933505:0 Alden Chu

crwdns2933769:0crwdne2933769:0
crwdns2933771:0crwdne2933771:0
crwdns2933801:0crwdne2933801:0

crwdns2933807:0crwdne2933807:0

+[* black] Determine if the capacitor or the fuse has failed. Using a Capacitance meter measure the capacitor, it should report a value of 130µF. If the capacitor value reported is close then use a voltmeter with continuity testing to probe the fuse, if there is no continuity then the fuse is broken.