crwdns2915892:0crwdne2915892:0
The Rival single cup coffee maker has a heating element that is prone to breaking. If the device is left on for too long, the heating element can over heat and stop working.
crwdns2942213:0crwdne2942213:0
-
-
Remove the three 16 mm tri-point screws from the base plate.
-
-
-
Remove the base plate by pressing the plastic body away from the metal plate with your thumbs.
-
-
-
Remove the 8mm Phillips screw that attaches the power button to the inside of the coffee maker.
-
-
-
Use a flat head screwdriver to pry the power button from its slot in the body of the device.
-
-
-
-
Clean both the button and its slot before replacing the power button.
-
-
-
Remove the two 8 mm Phillips screws from the plastic body.
-
-
-
Remove the two 8 mm Phillips screws from the chassis of coffee maker.
-
Pull back the metal backing from the plastic body.
-
-
-
Remove the four 8 mm Phillips screws from the inner plastic body.
-
-
-
Flip the device upside down and remove the outer plastic body from the device by pulling straight up.
-
-
-
Remove the two 8 mm Phillips screws from the metal backing.
-
-
-
Remove the 4 springs holding the water tubes by squeezing the 2 prongs together.
-
-
-
Bend the heating element back and forth to wiggle the water tubes loose from the plastic.
-
To reassemble your device, follow these instructions in reverse order.
To reassemble your device, follow these instructions in reverse order.
crwdns2935221:0crwdne2935221:0
crwdns2935227:0crwdne2935227:0