crwdns2933423:0crwdne2933423:0

Pentax Spotmatic Light Meter Calibration

crwdns2942213:0crwdne2942213:0

  1. Pentax Spotmatic Light Meter Calibration, Open film door: crwdns2935265:01crwdnd2935265:01crwdnd2935265:01crwdne2935265:0
    • Open the flim door.

  2. Pentax Spotmatic Light Meter Calibration, Remove the rewind knob: crwdns2935265:02crwdnd2935265:01crwdnd2935265:03crwdne2935265:0 Pentax Spotmatic Light Meter Calibration, Remove the rewind knob: crwdns2935265:02crwdnd2935265:02crwdnd2935265:03crwdne2935265:0 Pentax Spotmatic Light Meter Calibration, Remove the rewind knob: crwdns2935265:02crwdnd2935265:03crwdnd2935265:03crwdne2935265:0
    • Place a thin, sturdy tool in the spindle fork.

    • Unscrew the rewind knob.

    • Use a spanner wrench to unscrew the retaining nut.

    • Remove the film reminder

    • Remove the spring washer.

    • Remove the friction plate.

    • Keep the film door open for the duration of the light meter adjustment. It can be difficult to open without the rewind knob installed.

    • Mount a lens on the camera.

    • Create a scene of known brightness in front of the camera.

    • Adjust the aperture, shutter speed and ISO to achieve proper exposure for the chosen scene.

    • Switch on the light meter.

  3. Pentax Spotmatic Light Meter Calibration, Make adjustments: crwdns2935265:04crwdnd2935265:01crwdnd2935265:02crwdne2935265:0 Pentax Spotmatic Light Meter Calibration, Make adjustments: crwdns2935265:04crwdnd2935265:02crwdnd2935265:02crwdne2935265:0
    • Use a pick to adjust the variable resistor through the opening in the top plate.

    • Turn it until the needle in the viewfinder is centered in the opening, indicating a proper exposure.

    • The adjustment resistor shown with the top cover removed.

    • Repeat steps 3 and 4 for several different light levels.

    • Since the Spotmatic only has one adjustment resistor, it may not be possible to center the needle at every light level. Make compromises as necessary.

crwdns2915888:0crwdne2915888:0

To reassemble your device, follow these instructions in reverse order.

Sam Gustafson

crwdns2935283:009/01/22crwdne2935283:0

7,862 crwdns2915208:0crwdne2915208:0

crwdns2935297:049crwdne2935297:0

crwdns2947412:00crwdne2947412:0

crwdns2917038:0crwdne2917038:0

crwdns2936625:0crwdne2936625:0:

crwdns2936751:024crwdne2936751:0 2

crwdns2936753:07crwdne2936753:0 15

crwdns2936753:030crwdne2936753:0 71

crwdns2942667:0crwdne2942667:0 552