crwdns2933423:0crwdne2933423:0

Moen Posi-Temp Cartridge Part #1112b Replacement

crwdns2942213:0crwdne2942213:0

  1. Moen Posi-Temp Cartridge Part #1112b Replacement, Moen Posi-Temp Cartridge Part #1112b: crwdns2935265:01crwdnd2935265:01crwdnd2935265:01crwdne2935265:0
    • Turn the water shutoff valve counter-clockwise to the "off" position.

  2. Moen Posi-Temp Cartridge Part #1112b Replacement: crwdns2935265:02crwdnd2935265:01crwdnd2935265:01crwdne2935265:0
    • Open both the hot and cold taps of a nearby faucet or shower until the water no longer flows.

  3. Moen Posi-Temp Cartridge Part #1112b Replacement: crwdns2935265:03crwdnd2935265:01crwdnd2935265:02crwdne2935265:0 Moen Posi-Temp Cartridge Part #1112b Replacement: crwdns2935265:03crwdnd2935265:02crwdnd2935265:02crwdne2935265:0
    • Turn the handle of the shower valve 180 degrees until it is in the "up" or "on" position.

  4. Moen Posi-Temp Cartridge Part #1112b Replacement: crwdns2935265:04crwdnd2935265:01crwdnd2935265:02crwdne2935265:0 Moen Posi-Temp Cartridge Part #1112b Replacement: crwdns2935265:04crwdnd2935265:02crwdnd2935265:02crwdne2935265:0
    • Unscrew the handle screw with an Allen wrench.

    • Remove the handle.

  5. Moen Posi-Temp Cartridge Part #1112b Replacement: crwdns2935265:05crwdnd2935265:01crwdnd2935265:02crwdne2935265:0 Moen Posi-Temp Cartridge Part #1112b Replacement: crwdns2935265:05crwdnd2935265:02crwdnd2935265:02crwdne2935265:0
    • Remove the handle adaptor screw with a Phillips screwdriver.

    • Remove the handle adaptor simply by pulling it out.

  6. Moen Posi-Temp Cartridge Part #1112b Replacement: crwdns2935265:06crwdnd2935265:01crwdnd2935265:01crwdne2935265:0
    • Pull out the white key/adjustable limit stop.

  7. Moen Posi-Temp Cartridge Part #1112b Replacement: crwdns2935265:07crwdnd2935265:01crwdnd2935265:03crwdne2935265:0 Moen Posi-Temp Cartridge Part #1112b Replacement: crwdns2935265:07crwdnd2935265:02crwdnd2935265:03crwdne2935265:0 Moen Posi-Temp Cartridge Part #1112b Replacement: crwdns2935265:07crwdnd2935265:03crwdnd2935265:03crwdne2935265:0
    • Gently pull out the stop tube.

  8. Moen Posi-Temp Cartridge Part #1112b Replacement: crwdns2935265:08crwdnd2935265:01crwdnd2935265:03crwdne2935265:0 Moen Posi-Temp Cartridge Part #1112b Replacement: crwdns2935265:08crwdnd2935265:02crwdnd2935265:03crwdne2935265:0 Moen Posi-Temp Cartridge Part #1112b Replacement: crwdns2935265:08crwdnd2935265:03crwdnd2935265:03crwdne2935265:0
    • Using the Phillips head screwdriver, remove the two screws located at the top right corner and bottom left corner.

    • Remove the metal plate.

  9. Moen Posi-Temp Cartridge Part #1112b Replacement: crwdns2935265:09crwdnd2935265:01crwdnd2935265:03crwdne2935265:0 Moen Posi-Temp Cartridge Part #1112b Replacement: crwdns2935265:09crwdnd2935265:02crwdnd2935265:03crwdne2935265:0 Moen Posi-Temp Cartridge Part #1112b Replacement: crwdns2935265:09crwdnd2935265:03crwdnd2935265:03crwdne2935265:0
    • Slide the tip of needle-nose pliers under the notch of the retaining clip and pull the clip upwards.

  10. Moen Posi-Temp Cartridge Part #1112b Replacement: crwdns2935265:010crwdnd2935265:01crwdnd2935265:03crwdne2935265:0 Moen Posi-Temp Cartridge Part #1112b Replacement: crwdns2935265:010crwdnd2935265:02crwdnd2935265:03crwdne2935265:0 Moen Posi-Temp Cartridge Part #1112b Replacement: crwdns2935265:010crwdnd2935265:03crwdnd2935265:03crwdne2935265:0
    • Clamp firmly onto the brass tube with a pair of vice grips and gently but firmly pull out the cartridge.

  11. Moen Posi-Temp Cartridge Part #1112b Replacement: crwdns2935265:011crwdnd2935265:01crwdnd2935265:02crwdne2935265:0 Moen Posi-Temp Cartridge Part #1112b Replacement: crwdns2935265:011crwdnd2935265:02crwdnd2935265:02crwdne2935265:0
    • Insert the new Moen Posi-Temp cartridge.

  12. Moen Posi-Temp Cartridge Part #1112b Replacement: crwdns2935265:012crwdnd2935265:01crwdnd2935265:01crwdne2935265:0
    • Insert the new cartridge into the valve assembly.

    • Ensure that the H/C symbols are facing up.

    • Ensure that the notch on the brass tube is also facing up.

crwdns2915888:0crwdne2915888:0

To reassemble your device, follow these instructions in reverse order.

John Mendoza

crwdns2935283:009/17/20crwdne2935283:0

205 crwdns2915208:0crwdne2915208:0

crwdns2935295:0crwdne2935295:0

crwdns2915084:0crwdne2915084:0

York University, Team S3-G57, Melo-Thaiss Fall 2020 crwdns2935289:0York University, Team S3-G57, Melo-Thaiss Fall 2020crwdne2935289:0

YORK-MELO-THAISS-F20S3G57

crwdns2934841:01crwdne2934841:0

crwdns2935303:01crwdne2935303:0

crwdns2944067:00crwdne2944067:0

crwdns2917038:0crwdne2917038:0

crwdns2936625:0crwdne2936625:0:

crwdns2936751:024crwdne2936751:0 3

crwdns2936753:07crwdne2936753:0 15

crwdns2936753:030crwdne2936753:0 46

crwdns2942667:0crwdne2942667:0 1,157