How to flash MNT Reform LPC firmware

crwdns2942213:0crwdne2942213:0

  1. How to flash MNT Reform LPC firmware, Remove Bottom Plate Screws: crwdns2935265:01crwdnd2935265:01crwdnd2935265:01crwdne2935265:0
    • Remove the following screws securing the transparent acrylic bottom plate to the main box:

    • Ten M2×6mm silver Phillips screws

  2. How to flash MNT Reform LPC firmware, Remove Bottom Plate: crwdns2935265:02crwdnd2935265:01crwdnd2935265:01crwdne2935265:0
    • Lift the bottom plate and set it aside.

    • Before servicing anything on the inside, make sure to remove all battery cells.

  3. How to flash MNT Reform LPC firmware, Set LPCPROG switch to ON: crwdns2935265:03crwdnd2935265:01crwdnd2935265:02crwdne2935265:0 How to flash MNT Reform LPC firmware, Set LPCPROG switch to ON: crwdns2935265:03crwdnd2935265:02crwdnd2935265:02crwdne2935265:0
    • Use a spudger or your fingernail to set the DIP switch LPCP to ON.

    • The LPCP switch is located on the motherboard, between the CPU module and trackball or trackpad.

  4. How to flash MNT Reform LPC firmware, Press LPCRESET: crwdns2935265:04crwdnd2935265:01crwdnd2935265:01crwdne2935265:0
    • Use a spudger or your finger to press the LPCRST button next to the DIP switch from the previous step.

  5. How to flash MNT Reform LPC firmware, Plug in a USB cable: crwdns2935265:05crwdnd2935265:01crwdnd2935265:01crwdne2935265:0
    • Connect a Micro-USB cable into the LPC USB port.

    • On newer revisions of the Reform, the Micro-USB port has been replaced with a USB type-C port.

  6. How to flash MNT Reform LPC firmware, Flash the LPC firmware: crwdns2935265:06crwdnd2935265:01crwdnd2935265:01crwdne2935265:0
    • Plug the other end of the cable into another computer. The system controller's memory appears as a virtual flash drive on that computer.

    • Open a terminal and navigate to the reform2-lpc-fw folder you've downloaded from the Reform repository.

    • Check lsblk or dmesg -w to find out which drive the LPC shows up as, then edit flash.sh with the correct path to the virtual flash drive (e.g. /dev/sdx).

    • Double-check the path to make sure it is correct, as entering the wrong one could destroy data on your computer!

    • Execute flash.sh as root.

  7. How to flash MNT Reform LPC firmware, Unplug the USB cable: crwdns2935265:07crwdnd2935265:01crwdnd2935265:01crwdne2935265:0
    • Disconnect the USB cable from the LPC USB port.

  8. How to flash MNT Reform LPC firmware, Set LPCPROG switch to OFF: crwdns2935265:08crwdnd2935265:01crwdnd2935265:02crwdne2935265:0 How to flash MNT Reform LPC firmware, Set LPCPROG switch to OFF: crwdns2935265:08crwdnd2935265:02crwdnd2935265:02crwdne2935265:0
    • Use a spudger or your fingernail to set the DIP switch LPCP to OFF, which is the side labeled "1".

  9. How to flash MNT Reform LPC firmware, Press LPCRESET again: crwdns2935265:09crwdnd2935265:01crwdnd2935265:01crwdne2935265:0
    • Use a spudger or your finger to press the LPCRST button again.

crwdns2915888:0crwdne2915888:0

To reassemble your device, follow steps 1 and 2 in reverse order. Ensure that no cables are squeezed when replacing the bottom plate. Don't overtighten screws.

crwdns2935227:0crwdne2935227:0

Neelfyn

crwdns2935283:005/13/14crwdne2935283:0

972 crwdns2915208:0crwdne2915208:0

crwdns2935297:09crwdne2935297:0

crwdns2944067:00crwdne2944067:0

crwdns2917038:0crwdne2917038:0

crwdns2936625:0crwdne2936625:0:

crwdns2936751:024crwdne2936751:0 3

crwdns2936753:07crwdne2936753:0 10

crwdns2936753:030crwdne2936753:0 65

crwdns2942667:0crwdne2942667:0 695