There are a number of potential causes if your Honeywell HT900C fan does not start when you turn it on, including the fan motor being damaged from overuse, the fan being misaligned, etc. The fan motor is the most common culprit because it drives the rest of the fan. Our instructions will guide you through disassembling the old motor and installing the new one. All that is required is a screwdriver and some lubricant, both of which can be found in almost every home.
crwdns2942213:0crwdne2942213:0
-
-
Remove the six 15 mm screws securing the fan's frame to its outer ring on the back using a Phillips #1 screwdriver.
-
-
-
To gain access to the fan's inner workings, gently pull the blade cover away from the main body.
-
-
-
Remove the two 36 mm screws from the metal plate located behind the blades using a Phillips #1 screwdriver.
-
-
-
-
Carefully pull the motor it out of its resting position and tilt it forward to access the back of the motor.
-
-
-
Remove two 10 mm screws from the motor's back using a Phillips #1 screwdriver.
-
-
-
Remove the 20 mm screws beside the fan blade using a Phillips #1 screwdriver.
-
-
-
Carefully remove the circular motor from the square holder.
-
-
-
Remove the metal washer from the axle.
-
-
-
Replace the old motor with a new one, and you're done!
-
To reassemble your device, follow these instructions in reverse order.
To reassemble your device, follow these instructions in reverse order.
crwdns2935221:0crwdne2935221:0
crwdns2935227:0crwdne2935227:0