crwdns2915892:0crwdne2915892:0
If you're encountering issues as a result from the scanner bed, this is where you will want to start.
To replace the glass scanner bed, you must:
- Remove the two plastic bars that holds the scanner bed in place.
- Carefully remove the glass scanner bed to add the replacement.
crwdns2942213:0crwdne2942213:0
- 
   
   - 
                     
            Open up your Canon CanoScan N670U to an upright position. 
 
- 
                     
            
- 
   
   - 
                     
            Turn your device so that you're facing the long side of the Canon CanoScan N670U. 
- 
                     
            Locate the small crevice between the plastic components of the scanner bed and the scanner base. 
 
- 
                     
            
- 
   
   - 
                     
            Carefully insert a metal spudger tool in the crevice and slowly cut through the adhesive between the plastic components. 
 
- 
                     
            
- 
                     
                                                
- 
   
   - 
                     
            Once the adhesive strip is sliced through, the plastic bar that is attached should release. Set aside the plastic bar. 
 
- 
                     
            
- 
   
   - 
                     
            Repeat steps 2-4 for the other side of the scanner. 
 
- 
                     
            
- 
   
   - 
                     
            Use your hands or a metal spudger tool to push the plastic bar at the bottom of the glass scanner bed forward until you can't push it any farther. 
 
- 
                     
            
- 
   
   - 
                     
            Insert the metal spudger tool underneath the glass scanner bed. The front of the scanner bed should be resting on top of the tool. 
 
- 
                     
            
- 
   
   - 
                     
            Slowly pull the glass scanner bed towards you and set the piece aside. 
 
- 
                     
            
- 
   
   - 
                     
            Replace your defective glass scanner bed with a new one. 
 
- 
                     
            
To reassemble your device, follow these instructions in reverse order.
To reassemble your device, follow these instructions in reverse order.
crwdns2935221:0crwdne2935221:0
crwdns2935227:0crwdne2935227:0