crwdns2915892:0crwdne2915892:0
This guide for the Bissell CleanView Compact 3508 will give you step-by-step instructions to separate the vacuum chamber/motor from the bottom, brush, and wheels. From there, you can replace either section or have access to more parts.
crwdns2942213:0crwdne2942213:0
-
-
With the vacuum in an upright position, press the latch on the rear of the spine to remove the handle from the vacuum.
-
-
-
Use a Phillips #2 screwdriver to remove the five 20.7 mm screws on the underside of the brush roll cover.
-
-
-
Use a pry tool or flathead screwdriver to disengage the two retaining clips securing the brush roll cover.
-
Remove the brush roll cover.
-
-
-
-
Disconnect the main black hose from its lower attachment point.
-
-
-
Use a Phillips #2 screwdriver to remove the two 20.7 mm screws from the lower hose attachment point.
-
-
-
Use a Phillips #2 screwdriver to remove the four 20.7 mm screws on the upper cover plates.
-
Remove the two upper cover plates.
-
-
-
Gently pull the top half up and to the side away from the drive shaft to separate both halves.
-
Pull the belt through the socket, and remove the belt from the drive shaft.
-
Now your Bissell CleanView 3508 is separated from the top and bottom. To reassemble your device, follow these instructions in reverse order.
Now your Bissell CleanView 3508 is separated from the top and bottom. To reassemble your device, follow these instructions in reverse order.