crwdns2915892:0crwdne2915892:0
The battery can go bad on many devices. This guide includes removing the back plate and then detaching the battery from the rest of the watch.
crwdns2942213:0crwdne2942213:0
-
-
Wedge a plastic opening tool between band contacts.
-
-
-
Push in plastic opening tool until the components click and pop out of the holder.
-
Repeat steps for other band.
-
-
-
-
Remove four 4mm screws using a PH000 screwdriver.
-
Remove back plate.
-
-
crwdns2935267:0crwdne2935267:0Tweezers$4.99
-
Use tweezers to remove elastomeric, or zebra, connector.
-
-
-
Use the flat end of the spudger to carefully lift the battery until adhesive seal is broken.
-
-
-
Use the pointy edge of the spudger tool to detach battery leads from the circuit board.
-
To reassemble your device, follow these instructions in reverse order.
To reassemble your device, follow these instructions in reverse order.
crwdns2935221:0crwdne2935221:0
crwdns2935229:02crwdne2935229:0