crwdns2942213:0crwdne2942213:0
-
-
Unscrew the two screws on the handle with the spanner screwdriver.
-
-
-
Pull the case in opposite directions.
-
-
-
Unscrew the remaining two screws inside the handle with the Phillips screwdriver.
-
-
-
-
Push the inner components out of the handle.
-
-
-
Locate the thermal fuse.
-
Test the thermal fuse for continuity using the multimeter.
-
The circuit is closed and properly functioning if the multimeter displays varying numbers.
-
The circuit is open if the multimeter displays non-varying numbers or no numbers at all.
-
-
-
To replace the thermal fuse, use the prying tool to extract the object.
-
-
-
Replace the old thermal fuse by a new one.
-
To reassemble your device, follow these instructions in reverse order.
To reassemble your device, follow these instructions in reverse order.
crwdns2935221:0crwdne2935221:0
crwdns2935229:02crwdne2935229:0
crwdns2947412:02crwdne2947412:0
Does anybody know what is the small silver cylinder next to the thermal fuse? It is inline with the neutral AC from the handle switch, looks like it could be a diode or possibly a resistor, though it really resembles nothing I have seen before. My inoperable unit shows no continuity through this device either direction, so I presume it is bad….but I have no idea what to replace it with!
This is the thermostat, not the “thermal fuse’’ !!