crwdns2915892:0crwdne2915892:0
The fan regulates air flow to the Time Capsule allowing the internal components to maintain optimal temperature. If the fan has failed, it is very easy to replace and needs very little tools.
crwdns2942213:0crwdne2942213:0
-
-
Turn the device upside down to reveal the rubber section of the back plate. Using a metal spudger, carefully wedge the blunt tip into the space between the aluminum back plate and the rubber, separating the two pieces.
-
Depending on air temperature and how set the adhesive is, you may need to spend some time warming the back plate with a hot plate (on low) or hair dryer.
-
-
-
Remove the ten 3mm screws with a Phillips #00 screwdriver.
-
-
-
-
The fan affixed to the back plate is connected to the logic board. A small wire must be detached to fully remove the back plate.
-
Pull the base of the wire close to the logic board and the connector will pop off.
-
-
-
Orientate the back plate so that the fan is facing away from you.
-
Use the #0 Phillips Screw Drive to push the rubber shock mounts through the back plate.
-
To reassemble your device, follow these instructions in reverse order.
To reassemble your device, follow these instructions in reverse order.
crwdns2935221:0crwdne2935221:0
crwdns2935229:03crwdne2935229:0
crwdns2947412:02crwdne2947412:0
Hi where can I find the new rubber shock mount replacement for A-1254 fan replacement? thx.
How do I get the rubber feet off the old fan and put them on the new fan?