crwdns2944766:0crwdne2944766:0
crwdns2918718:0crwdne2918718:0crwdns2935091:0crwdnd2935091:0crwdne2935091:0
crwdns2916646:0crwdne2916646:0
BC BIOMEDICAL SA-2600 SERIES
ELECTRICAL SAFETY ANALYZER WITH PATIENT SIMULATOR
The SA-2600 Series is an automated Electrical Safety Analyzer with a built-in Patient Simulator. It allows for a multitude of tests to be performed on a device using the same unit and lead connections. It provides a full Electrical Safety Analyzer, as well as ECG Simulation with four waveforms with constant QRS duration and six machine performance testing waveforms. There is Patient Lead testing for 10 inputs. There are programmable autosequences to allow for limited user intervention testing. The following are highlights of some of the main features:
SA-2600 Main Features
- 4.3" LCD COLOR TOUCH DISPLAY
- AUDIO FEEDBACK
- TOUCH CONTROL KEYS – NO KNOBS
- 10 UNIVERSAL PATIENT LEAD INPUTS
- HIGH IMPACT PLASTIC CASE
- CUSTOMIZABLE AUTOSEQUENCES
- FIXED GENERIC AUTOSEQUENCES
Safety Analyzer Features
- LINE VOLTAGE MEASUREMENT
- DEVICE UNDER TEST CURRENT MEASUREMENT
- EARTH / GROUND LEAD RESISTANCE
- EARTH / GROUND LEAKAGE CURRENT
- ENCLOSURE / CHASSIS LEAKAGE CURRENT
- PATIENT LEAD TO LEAD LEAKAGE CURRENT
- PATIENT LEAD TO EARTH / GROUND LEAKAGE CURRENT
- PATIENT ISOLATION LEAKAGE CURRENT
- POINT TO POINT RESISTANCE
- POINT TO POINT LEAKAGE CURRENT
- TRUE RMS MEASUREMENTS
- AAMI ES1-1993 or IEC 60601 SELECTABLE TEST LOADS
- 90 TO 264 VAC OPERATION
- 20 AMP RATING (SA-2600 and SA-2600-INTL Models)
- 10 AMP RATING (SA-2600-AUS Models)
- SELF TEST POINTS
- EXTERNALLY REPLACEABLE GROUND FUSE
Patient Simulator Features
- ECG: 30, 60, 120 AND 240 BPM
- SINE: 10, 60 AND 100 Hz
- SQUARE: 0.125 AND 2.0 Hz
- TRIANGLE: 2 Hz
- HIGH LEVEL OUTPUT (1 V p-p)
- AMPLITUDE ACCURACY: +/- 2%
- FREQUENCY ACCURACY: +/- 0.5%
Available Models
SA-2600 – Standard Model
Standard model with hospital-grade NEMA 5-15P line plug and hospital-grade NEMA 5-20R DUT test receptacle for use in the US and other compatible countries.
SA-2600-INTL – International Model
International model, IEC C20 receptacle pigtail (must use country-specific line cord – see accessories section) and universal DUT test receptacle that works with the following country-specific plugs:
- NEMA 5-15P, NEMA 5-20P, NEMA 6-15P and NEMA 6-20P (US/North America)
- UK1-13P and UK3-5P (UK)
- SW1-10P (Switzerland)
- IT1-10P (Italy)
- IS1-16P (Israel)
- JA1-15P (Japan)
- EU1-16P (Euro) CEE 7/7 "SCHUKO" (Note: Must use SCHUKO grounding adapter to perform leakage measurements, see optional accessories section)
- DE1-13P (Denmark) (Note: No earth/ground pin, therefore leakage measurements not applicable)
- EUROPLUG CEE 7/16 (Note: No earth/ground pin, therefore leakage measurements not applicable)
SA-2600-AUS – Australian Model
Australian model, AU1-10P line plug and AU1-10R DUT test receptacle for use in Australia/New Zealand and other compatible countries.
Standard Accessories
- BC20-20110 8 FT Chassis Test Lead (Black)
- BC20-17026 Ground Pin
- BC20-30107 Soft Carrying Case
- UF-0250-01 Replacement Ground Leg Fuse
- BC20-204XX Power Cord (SA-2600-INTL Only) – Refer to page 6
Optional Accessories
- BC20-20111 8 FT External Test Lead (Red)
- BC20-20112 16 FT Chassis Test Lead (Black)
- BC20-20113 16 FT External Test Lead (Red)
- BC20-20200 Replacement SA-2600-INTL DUT International Receptacle Adapter
- BC20-20221 SCHUKO Grounding Adapter
- BC20-41377 Micro USB Cable (Micro to USB A)
SA-2600-INTL Line Cords
Refer to page 6 for details:
- BC20-20400 NEMA 5-20P Plug Line Cord (USA/North America)
- BC20-20401 JA1-15P Plug Line Cord (Japan)
- BC20-20402 UK1-13P Plug Line Cord (UK)
- BC20-20403 CEE 7/7 "SCHUKO" Plug Line Cord (Euro)
Note: Includes BC20-20221 Grounding Adapter - BC20-20409 BSS546A Plug Line Cord (India/South Africa)
- BC20-20410 SW1-10P Plug Line Cord (Switzerland)
- BC20-20412 IT1-10P Plug Line Cord (Italy)
- BC20-20416 Australia Plug Line Cord