Sorry for the delay on this. Life has been very hectic.
First of all, this is very me levels of working out a problem. I mean that as a compliment I promise. I would also read these as Rx and Tx lines. There are more lines on the reverse side of the board for the remaining Rx/Tx lines.
Because those generally occur in pairs we can make an assumption about values. Components on correlated data pairs should be the same. I observed this in practice when I was measuring. I took them out of circuit, since that's the best way to measure capacitance.
-
[image|3660395]
+
[image|3660410]
The components highlighted in orange on the left hand side both measured about 450 nF.
The components on the right, highlighted in yellow were both about 300 nF.
I actually expected these to all be the same so I am glad I measured all of them.