-Why isn't my ups turning on
+Why isn't my UPS turning on?

crwdns2934249:0crwdne2934249:0:

-I got this UPS (Powercom BNT V1.3) from an uncle and it's decades old. It's a line interactive model and was working fine other than its obviously dead battery.
+I have a ***Powercom BNT V1.3 UPS***, which I got from my uncle. It's a line-interactive model and decades old. Other than its obviously dead battery, it was working fine when I first received it.
-So I tried to see if I could revive the battery by adding water to the cells since they were dry.
+=== What I Did ===
+Since the battery was dry, I attempted to revive it by adding water to the cells. Afterward:
-I then reconnected the battery and turned the ups on to start charging the battery. After a while of charging I heard a pop and saw a flash of light. I then immediately turned it off. And promptly smelled the magic smoke from one of the components.
+# I reconnected the battery.
+# I turned the UPS on to start charging the battery.
+Unfortunately, after charging for a while, I heard a ***pop*** and saw a ***flash of light***. I immediately turned the UPS off and noticed the smell of "magic smoke" from one of the components.
-It hasn't started since. And the I've since learned that the battery has an internal short.
+I later found out the battery had an ***internal short***. Since then, the UPS hasn’t started.
-I can't seem to identify which component died (if it did).
+=== What I’ve Tried So Far ===
+* Tested the ***transformer*** for continuity: it seems fine.
+* Fixed ***two broken traces*** on the back of the circuit board (see images below).
+=== Images ===
+[image|3493304][br]
+[image|3493307][br]
+[image|3493308] [br]
+[image|3493303]
-I have tested the transformer for continuity and it seems to be fine. And have also fixed 2 broken traces on the back of the circuit board(images attached).
+=== What Should I Check Next? ===
+I am unable to identify which component might have failed. Any advice on what to check next or how to proceed would be greatly appreciated!
-[image|3493304]
-
-What should I check next, I don't know what to do next.
-
-[image|3493307]
-
-[image|3493308]
-
-[image|3493303]
+=== Notes ===
+* The UPS has not turned on since the incident.
+* I suspect some components may have been damaged, but I’m not sure which ones.

crwdns2866306:0crwdne2866306:0:

UPS

crwdns2915684:0crwdne2915684:0:

open

crwdns2934241:0crwdne2934241:0 Dominic miranda

crwdns2947189:0crwdne2947189:0:

Why isn't my ups turning on

crwdns2934249:0crwdne2934249:0:

I got this UPS (Powercom BNT V1.3) from an uncle and it's decades old. It's a line interactive model and was working fine other than its obviously dead battery.

So I tried to see if I could revive the battery by adding water to the cells since they were dry.

I then reconnected the battery and turned the ups on to start charging the battery. After a while of charging I heard a pop and saw a flash of light. I then immediately turned it off. And promptly smelled the magic smoke from one of the components.

It hasn't started since. And the I've since learned that the battery has an internal short.

I can't seem to identify which component died (if it did).

I have tested the transformer for continuity and it seems to be fine. And have also fixed 2 broken traces on the back of the circuit board(images attached).

[image|3493304]

What should I check next, I don't know what to do next.