Hi @ashley677
-It could be a faulty hot water inlet solenoid valve
-
-Here's a [https://www.youtube.com/watch?v=-OP7Ky2izkQ|video] that ''might'' help you to replace it.
+It could be a faulty hot water inlet solenoid valve.
You can test if the valve is electrically OK from the control board to the valve, by using the [document|32180|mini manual] for the washer. Enter the diagnostic mode as shown in the manual and check the status lights when in knob position #5 ''hot water valve active''. You can also disconnect the power and connect an Ohmmeter between the valve and the purple wire on terminal #2 of the 10 pin harness cable connector on the board and check that there's continuity in the wiring i.e. no loose connection between the valve and the control board.
If the valve is mechanically faulty then unfortunately they cannot be repaired, they have to be replaced. Also it comes as a complete module along with the cold water inlet valve so you cannot just buy the one valve. Search online for ''WH13X10053'' to find suppliers that suit you best.
+
+Here's a [link|https://www.youtube.com/watch?v=-OP7Ky2izkQ|video] that ''might'' help you to replace it.

crwdns2915684:0crwdne2915684:0:

open

crwdns2934241:0crwdne2934241:0 jayeff

crwdns2934249:0crwdne2934249:0:

Hi @ashley677

It could be a faulty hot water inlet solenoid valve

Here's a [https://www.youtube.com/watch?v=-OP7Ky2izkQ|video] that ''might'' help you to replace it.

You can test if the valve is electrically OK from the control board to the valve, by using the [document|32180|mini manual] for the washer. Enter the diagnostic mode as shown in the manual and check the status lights when in knob position #5 ''hot water valve active''. You can also disconnect the power and connect an Ohmmeter between the valve and the purple wire on terminal #2 of the 10 pin harness cable connector on the board and check that there's continuity in the wiring i.e. no loose connection between the valve and the control board.

If the valve is mechanically faulty then unfortunately they cannot be repaired, they have to be replaced. Also it comes as a complete module along with the cold water inlet valve so you cannot just buy the one valve. Search online for ''WH13X10053'' to find suppliers that suit you best.