A microwave that is tripping a circuit breaker can be caused by a shorted magnetron. You can determine that a magnetron has shorted by contacting one multimeter lead to one of the magnetron's terminals and the other lead to the casing. If meter display indicates that electrical continuity is present between any of the terminals and the casing, the magnetron has shorted and will need to be replaced.
PART
-https://www.repairclinic.com/PartDetail/Magnetron/5304519335/4920514
+https://www.ifixit.com/products/5304519335-electrolux-microwave-magnetron

crwdns2915684:0crwdne2915684:0:

open

crwdns2934241:0crwdne2934241:0 mayer

crwdns2934249:0crwdne2934249:0:

A microwave that is tripping a circuit breaker can be caused by a shorted magnetron. You can determine that a magnetron has shorted by contacting one multimeter lead to one of the magnetron's terminals and the other lead to the casing. If meter display indicates that electrical continuity is present between any of the terminals and the casing, the magnetron has shorted and will need to be replaced.