crwdns2933423:0crwdne2933423:0
crwdns2918538:0crwdne2918538:0

crwdns2934243:0crwdne2934243:0 Jim Gamblain

crwdns2934249:0crwdne2934249:0:

[br]
-That's the polyfuse. Disconnect power, and you should read close to 0 ohms across it. With power applied, you should read around +5v.
+That's the polyfuse. Disconnect power, and you should read close to 0 ohms across it. With power applied, you should read around +5v from either end to ground. reading an open during the ohm test tells you it needs time to reset. Same thing with reading +5 from only one side. Fuse check passes if you get close to 0 ohms and read +5 on both sides when powered up.

crwdns2915684:0crwdne2915684:0:

open

crwdns2934241:0crwdne2934241:0 Jim Gamblain

crwdns2934249:0crwdne2934249:0:

[br]
That's the polyfuse. Disconnect power, and you should read close to 0 ohms across it. With power applied, you should read around +5v.

crwdns2915684:0crwdne2915684:0:

open